<releasenotes productname="InduSoft Web Studio">
  <version>
    <releaseversion> v6.1 + Service Pack 6</releaseversion>
    <releasedate>Monday, November 30, 2009</releasedate>
    <wi>
      <wiid>1141</wiid>
      <witype>Requirement</witype>
      <widesc>Added hardkey license support for CEView.</widesc>
    </wi>
    <wi>
      <wiid>1275</wiid>
      <witype>Requirement</witype>
      <widesc>Updated the software to ensure full compatibility with Microsoft Windows 7 (both 32-bits and 64-bits).</widesc>
    </wi>
    <wi>
      <wiid>1278</wiid>
      <witype>Requirement</witype>
      <widesc>Improved CEView to run on Windows CE devices that do not support DCOM. Only the OPC DA interface is still not supported, because it specifically requires DCOM.</widesc>
    </wi>
    <wi>
      <wiid>1387</wiid>
      <witype>Requirement</witype>
      <widesc>Added the entry "SecureViewerWatchDogTag" to the application file (application_name.app). This instructs the Secure Viewer to watch a specified tag (by default, the system tag ServerTime_), and if the tag value does not change before the timeout is reached -- indicating that the Server has failed or the Secure Viewer has otherwise lost its connection to the Server -- then the Secure Viewer automatically switches to the designated backup Server. The application file entry can be edited to specify a different tag.</widesc>
    </wi>
    <wi>
      <wiid>1389</wiid>
      <witype>Requirement</witype>
      <widesc>Added "Disable Commands" option to the screen attributes, to allow programmatic disabling of all user interaction in a specific screen.</widesc>
    </wi>
    <wi>
      <wiid>955</wiid>
      <witype>Change Request</witype>
      <widesc>Modified the Secure Viewer to be able to run remotely, with independent tag values and security, even when running on the same computer as the Server (i.e. Studio Manager). This can be enabled by selecting the option "Force remote behavior" in the Secure Viewer Configuration utility (ViewerCfg.exe).</widesc>
    </wi>
    <wi>
      <wiid>1022</wiid>
      <witype>Change Request</witype>
      <widesc>Introduced the SecureViewerReload function (from the Built-in Scripting Language) to reload the Secure Viewer with a different configuration file during runtime.</widesc>
    </wi>
    <wi>
      <wiid>1085</wiid>
      <witype>Change Request</witype>
      <widesc>Fixed an issue where the operator could not use Remote Desktop Client (RDC) to access the software running on another station. The issue was introduced in a previous release, when the hardkey licensing mechanism was modified to prevent mulitple simultaneous accesses of the same hardkey.</widesc>
    </wi>
    <wi>
      <wiid>1108</wiid>
      <witype>Change Request</witype>
      <widesc>Improved the external databases interface to provide more informative log messages, especially when the maximum number of database connections is reached.</widesc>
    </wi>
    <wi>
      <wiid>1190</wiid>
      <witype>Change Request</witype>
      <widesc>Modified the Application Tags database to support up to 65488 rows.</widesc>
    </wi>
    <wi>
      <wiid>1216</wiid>
      <witype>Change Request</witype>
      <widesc>Improved the external database interface to support SQL CE 3.0 and 3.5. Please see the documentation for information on how to configure these database connections.</widesc>
    </wi>
    <wi>
      <wiid>1259</wiid>
      <witype>Change Request</witype>
      <widesc>Implemented UNICODE capabilities when sending alarm e-mails or sending e-mails using the SendEMailExt function call.</widesc>
    </wi>
    <wi>
      <wiid>1311</wiid>
      <witype>Change Request</witype>
      <widesc>Improved the OPC Server module to automatically re-register itself whenever it is started, so that it always runs with the correct DCOM credentials.</widesc>
    </wi>
    <wi>
      <wiid>1360</wiid>
      <witype>Change Request</witype>
      <widesc>Updated the software to ensure full compatibility with Microsoft Windows 7 (both 32-bits and 64-bits).</widesc>
    </wi>
    <wi>
      <wiid>1384</wiid>
      <witype>Change Request</witype>
      <widesc>Improved the database interface to support the latest .Net connector for MySQL.</widesc>
    </wi>
    <wi>
      <wiid>1388</wiid>
      <witype>Change Request</witype>
      <widesc>Changed the layout of the Trend Control object to make it easier to select pens during runtime. This change affects Windows PC clients only, not Windows CE clients.</widesc>
    </wi>
    <wi>
      <wiid>1392</wiid>
      <witype>Change Request</witype>
      <widesc>Modified the external databases interface to refresh hostname every time a new connection is made.</widesc>
    </wi>
    <wi>
      <wiid>1407</wiid>
      <witype>Change Request</witype>
      <widesc>Modified CEServer and the Support Information dialog to indicate the correct operating system version for Windows 7 and Windows 2008.</widesc>
    </wi>
    <wi>
      <wiid>1418</wiid>
      <witype>Change Request</witype>
      <widesc>Improved the email interface to allow custom port numbers for SMTP and POP3 servers.</widesc>
    </wi>
    <wi>
      <wiid>664</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where, on Windows 64-bit operating systems, the operator could use keyboard shortcuts to switch tasks even when the security settings -- specifically "Task Switch Enabled" and "Disable Task Manager" -- were configured to prevent it. See also items 1083 and 1397.</widesc>
    </wi>
    <wi>
      <wiid>712</wiid>
      <witype>Issue</witype>
      <widesc>Updated the novaPDF printer utility to work correctly on Windows 64-bit operating systems and Windows XP Embedded devices.</widesc>
    </wi>
    <wi>
      <wiid>836</wiid>
      <witype>Issue</witype>
      <widesc>Modified expression parsers to properly indicate an error when an expression uses incorrect syntax, such as "(Function)" instead of "Function()".</widesc>
    </wi>
    <wi>
      <wiid>917</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Trend Control object to handle floating point values in the "Axes &gt; Time" field when Period Type is set to "Time Before Now". Also, the object will now update the value of the tag configured in the "Axes &gt; Time" field according to user input during runtime (e.g. when the object's X-axis scroll bar is used to change the time period being displayed).</widesc>
    </wi>
    <wi>
      <wiid>922</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue that prevented the Service created by the "Service Configuration" utility (Tools &gt; Service Configuration) from starting automatically when the computer boots. Also, the name of the Service will now show the full product name instead of only the company name.</widesc>
    </wi>
    <wi>
      <wiid>926</wiid>
      <witype>Issue</witype>
      <widesc>Modified the "Service Configuration" utility to run as Administrator on Windows Vista, even when the user does not explicitly choose to run it as Administrator.</widesc>
    </wi>
    <wi>
      <wiid>928</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where, on Windows Vista, new application projects would sometimes be saved in locations other than the user's Documents folder.</widesc>
    </wi>
    <wi>
      <wiid>931</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the Trend Control object did not adjust for Daylight Saving Time on Windows CE devices.</widesc>
    </wi>
    <wi>
      <wiid>932</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where a Linked Symbol object would sometimes lose its custom property values when the Master Object was changed.</widesc>
    </wi>
    <wi>
      <wiid>934</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue that sometimes caused the Remote LogWin utility to close when attempting to save the log to disk.</widesc>
    </wi>
    <wi>
      <wiid>953</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Viewer to properly display scroll bars when the size of an application screen is larger than the size of the Viewer window.</widesc>
    </wi>
    <wi>
      <wiid>954</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue that caused the External Databases interface to insert a NULL value for Boolean tags, instead of the correct value of 0 or 1.</widesc>
    </wi>
    <wi>
      <wiid>961</wiid>
      <witype>Issue</witype>
      <widesc>Modified Event logging to save the User Name with the Event.</widesc>
    </wi>
    <wi>
      <wiid>964</wiid>
      <witype>Issue</witype>
      <widesc>Updated the context-sensitive help to include new items in the user interface.</widesc>
    </wi>
    <wi>
      <wiid>973</wiid>
      <witype>Issue</witype>
      <widesc>Modified the algorithm of the Global Replace feature to properly replace properties from Linked Symbols.</widesc>
    </wi>
    <wi>
      <wiid>980</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an error that occurred when an application project contained the maximum number of tags allowed by the program license and then the user tried to change the properties of a tag.</widesc>
    </wi>
    <wi>
      <wiid>981</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue that sometimes caused the Div/Add and Min/Max settings in a Drivers worksheet to be ignored, resulting in raw rather than scaled tag values being written to the target device.</widesc>
    </wi>
    <wi>
      <wiid>986</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the Global Replace tool did not replace tags in Linked Symbols in closed Screen files.</widesc>
    </wi>
    <wi>
      <wiid>994</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the PrintSetup function (from the Built-in Scripting Language) would not accept the printer selected by the user.</widesc>
    </wi>
    <wi>
      <wiid>995</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Reports task to properly handle situations where the user forgets to close the curly brackets around a tag or expression.</widesc>
    </wi>
    <wi>
      <wiid>997</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue that caused the Convert Resolution command (Tools &gt; Convert Resolution) to disable automatic screen scaling.</widesc>
    </wi>
    <wi>
      <wiid>998</wiid>
      <witype>Issue</witype>
      <widesc>Fixed logon issues in Mobile Access.</widesc>
    </wi>
    <wi>
      <wiid>999</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the FileWrite function (from the Built-in Scripting Language) to work properly when the same text file is being used by more than one Grid or Trend Control object.</widesc>
    </wi>
    <wi>
      <wiid>1002</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the Mobile Access server incorrectly incremented the number of connected users when a user disconnected without logging off — usually by closing the Web browser — and then attempted to reconnect.</widesc>
    </wi>
    <wi>
      <wiid>1006</wiid>
      <witype>Issue</witype>
      <widesc>Improved the performance of the Windows CE thin clients (both Web Thin Client and Secure Viewer) when accessing an application with an extremely long Global Procedures file.</widesc>
    </wi>
    <wi>
      <wiid>1007</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the Replace button (in the Object Properties dialog) to replace string values in Linked Symbols.</widesc>
    </wi>
    <wi>
      <wiid>1011</wiid>
      <witype>Issue</witype>
      <widesc>Improved performance when communicating with several devices at the same time.</widesc>
    </wi>
    <wi>
      <wiid>1017</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the RunGlobalProcedureOnServer function (from the Built-in Scripting Language) to work properly when the application is running as a Windows Service.</widesc>
    </wi>
    <wi>
      <wiid>1018</wiid>
      <witype>Issue</witype>
      <widesc>Modified the remote debugging tools (Remote Database Spy and Remote LogWin) to allow the user to cancel while tags are being loaded from the Server.</widesc>
    </wi>
    <wi>
      <wiid>1023</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the Execution Environment tool to download the correct firewall configuration to Window CE devices.</widesc>
    </wi>
    <wi>
      <wiid>1029</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where, on certain laptops running Windows Vista 64-bit, installing the software would disable the keyboard and touchpad.</widesc>
    </wi>
    <wi>
      <wiid>1034</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue that caused the Trend Control object to print only a blank page on certain printer models.</widesc>
    </wi>
    <wi>
      <wiid>1035</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the SetViewerInFocus function (from the Built-in Scripting Language) to work properly when the application viewer is minimized.</widesc>
    </wi>
    <wi>
      <wiid>1040</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where a Combo Box object with the Position dynamic applied to it sometimes changed values unexpectedly.</widesc>
    </wi>
    <wi>
      <wiid>1047</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the Wait function (from the Built-in Scripting Language) built-in function Wait() to work properly when used in VBScript.</widesc>
    </wi>
    <wi>
      <wiid>1048</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where, on some Windows CE devices, the Group column of an Alarm Control object would not update properly.</widesc>
    </wi>
    <wi>
      <wiid>1052</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the Mobile Access server would sometimes reject new connections after running for a long time.</widesc>
    </wi>
    <wi>
      <wiid>1059</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue that caused Remote Agent (running on Windows CE) to move to the background when the Setup button was clicked.</widesc>
    </wi>
    <wi>
      <wiid>1067</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the Alarm Control object to delete messages properly from the alarm history.</widesc>
    </wi>
    <wi>
      <wiid>1070</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the "history-to-text" conversion utility (HST2TXT.exe) to properly adjust for Daylight Saving Time.</widesc>
    </wi>
    <wi>
      <wiid>1072</wiid>
      <witype>Issue</witype>
      <widesc>Improved counting of connected users in Mobile Access.</widesc>
    </wi>
    <wi>
      <wiid>1078</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the ProductVersion function (from the Built-in Scripting Language) to return the correct version number when running the Viewer module.</widesc>
    </wi>
    <wi>
      <wiid>1083</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where, on Windows 64-bit operating systems, the operator could use keyboard shortcuts to switch tasks even when the security settings -- specifically "Task Switch Enabled" and "Disable Task Manager" -- were configured to prevent it. See also items 664 and 1397.</widesc>
    </wi>
    <wi>
      <wiid>1089</wiid>
      <witype>Issue</witype>
      <widesc>Improved communication with devices to prevent tag values from reverting (when Send Last State is selected) or "flickering" (when Send Every State is selected).</widesc>
    </wi>
    <wi>
      <wiid>1090</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where an object with both the Position and Bargraph dynamics applied to it would not behave properly.</widesc>
    </wi>
    <wi>
      <wiid>1091</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the Viewer module sometimes closed improperly after running an application that had the Virtual Keyboard/Keypad open.</widesc>
    </wi>
    <wi>
      <wiid>1103</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the Trend Control object to prevent overflow when drawing the pens. The overflow for huge values could cause unexpected behavior.</widesc>
    </wi>
    <wi>
      <wiid>1107</wiid>
      <witype>Issue</witype>
      <widesc>Modified the CEView PRO License and Runtime to support up to five different communication drivers in the same application.</widesc>
    </wi>
    <wi>
      <wiid>1110</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Format function (from the Built-in Scripting Language) to properly handle real values that are too big.</widesc>
    </wi>
    <wi>
      <wiid>1112</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the FileCopy function (from the Built-in Scripting Language) would not copy files to a computer's root directory.</widesc>
    </wi>
    <wi>
      <wiid>1148</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where deleting a tag from the application database would sometimes cause the Development Environment to close unexpectedly.</widesc>
    </wi>
    <wi>
      <wiid>1159</wiid>
      <witype>Issue</witype>
      <widesc>Modified the bargraph dynamic to work correctly on Windows Mobile 6.1. The previous implementation would not work when bargraph is at 0%.</widesc>
    </wi>
    <wi>
      <wiid>1163</wiid>
      <witype>Issue</witype>
      <widesc>Modified CEView to be able to run Math worksheets and Scripts from only the compiled files (*.mac and *.isc) in the application's Config folder. The source files (*.mat and *.is) can be safely deleted to protect intellectual property.</widesc>
    </wi>
    <wi>
      <wiid>1165</wiid>
      <witype>Issue</witype>
      <widesc>Modified the historical file saving to generate a new file if the user updates the month/year, the previous implementation would look only for the day.</widesc>
    </wi>
    <wi>
      <wiid>1175</wiid>
      <witype>Issue</witype>
      <widesc>Updated the e-mail features to work properly with some specific e-mail servers.</widesc>
    </wi>
    <wi>
      <wiid>1178</wiid>
      <witype>Issue</witype>
      <widesc>Fixed problem with execution environment, it would fail to connect if you keep connecting and disconnecting using a serial connection.</widesc>
    </wi>
    <wi>
      <wiid>1193</wiid>
      <witype>Issue</witype>
      <widesc>Fixed problem when removing tags from the Application Tags Database in certain application with too many Tags of Class Type</widesc>
    </wi>
    <wi>
      <wiid>1206</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the Trend Control object to properly draw a pen that has a Min/Max range outside of its Lo Limit/Hi Limit range. (For example, a Min/Max range of 0–19 and a Lo Limit/Hi Limit range of 20–80.)</widesc>
    </wi>
    <wi>
      <wiid>1207</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where, when a new application project was created with a Target Platform of "CEView", the Fmt setting of the Text I/O dynamic was always locked to "Auto".</widesc>
    </wi>
    <wi>
      <wiid>1210</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the Virtual Keypad to avoid truncating exponential values when the associated tag's specified Max is in scientific notation.</widesc>
    </wi>
    <wi>
      <wiid>1218</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue in Linked Symbols where editing a custom property with a direct tag reference would break indirect references (a.k.a. pointers) to the same tag. For example, #tagName:myStringTag and #tagName:@myStringTag. Now, when you change the direct tag reference, the indirect reference will be correctly updated to match.</widesc>
    </wi>
    <wi>
      <wiid>1256</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue in Linked Symbols where, if different class members and tag fields are associated with the same property (e.g. #Prop1:TagA.MemX-&gt;B0, #Prop1:TagA.MemrY-&gt;B1), then the Symbol Properties dialog wouldincorrectly include the class member in the editable/replaceable value. Now, the Custom Properties dialog will only show the main tag as editable/replaceable.</widesc>
    </wi>
    <wi>
      <wiid>1263</wiid>
      <witype>Issue</witype>
      <widesc>Modified Auto logoff feature for CEView to work properly on some specific devices.</widesc>
    </wi>
    <wi>
      <wiid>1276</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue in Linked Symbols where, in specific circumstances, the software would crash after the user edited a custom property in the Object Properties dialog.</widesc>
    </wi>
    <wi>
      <wiid>1312</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue in Alarms where the "Apply Period of Time to Each Day" option would not work when the historical data was being saved to an external database.</widesc>
    </wi>
    <wi>
      <wiid>1317</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where, when running an application in the Web Thin Client on Internet Explorer 8, cascading application dialogs would be disabled.</widesc>
    </wi>
    <wi>
      <wiid>1321</wiid>
      <witype>Issue</witype>
      <widesc>Modified the CnfEmail function to properly handle an empty string as a parameter for pop server on the 64 bit operating systems.</widesc>
    </wi>
    <wi>
      <wiid>1323</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where executing a Global Replace while screens were open might have caused the development software to crash.</widesc>
    </wi>
    <wi>
      <wiid>1338</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the runtime server may have frozen when running an application that called database functions in the Startup Script.</widesc>
    </wi>
    <wi>
      <wiid>1344</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the runtime server may have crashed if the application's Global Procedures script was edited during runtime.</widesc>
    </wi>
    <wi>
      <wiid>1383</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where running an application with Smart Message objects linked to text files would cause the runtime application viewer to crash.</widesc>
    </wi>
    <wi>
      <wiid>1390</wiid>
      <witype>Issue</witype>
      <widesc>Removed "Testing Hard Key" message from output log, because it is irrelevant to runtime performance.</widesc>
    </wi>
    <wi>
      <wiid>1393</wiid>
      <witype>Issue</witype>
      <widesc>Fixed issue with FOR NEXT when using math scripts on specific Windows CE devices.</widesc>
    </wi>
    <wi>
      <wiid>1397</wiid>
      <witype>Issue</witype>
      <widesc>Fixed an issue where the operator could use keyboard shortcuts to switch tasks or close the application even when the security settings were configured to prevent it.</widesc>
    </wi>
    <wi>
      <wiid>1416</wiid>
      <witype>Issue</witype>
      <widesc>Modified Support Information window to properly display remote device information on Windows 7 and Windows Vista.</widesc>
    </wi>
  </version>
  <version>
    <releaseversion> v6.1 + Service Pack 5</releaseversion>
    <releasedate>Thursday, January 15, 2009</releasedate>
    <wi>
      <wiid>461</wiid>
      <witype>Requirement</witype>
      <widesc>Modified the SNMP interface to support customized MIB files.</widesc>
    </wi>
    <wi>
      <wiid>467</wiid>
      <witype>Requirement</witype>
      <widesc>Created the option to "Read after writing" in the OPC Client worksheet. This option is useful to synchronize the values from the OPC Server with the values from the OPC Client, especially when the same item from the OPC Server can be updated either by the OPC Client or by the device (e.g.: PLC) connected to the OPC Server.</widesc>
    </wi>
    <wi>
      <wiid>469</wiid>
      <witype>Requirement</witype>
      <widesc>The driver task was modified to eliminate the limit of 81 characters when reading/writing string data from/to the device(s). This item will only be available for drivers using the new Driver Toolkit and that use the Driver Standard to set the string values.</widesc>
    </wi>
    <wi>
      <wiid>473</wiid>
      <witype>Requirement</witype>
      <widesc>Created the SNMPSet() built-in function, which allows the user to write values to OID addresses, using the SNMP protocol.</widesc>
    </wi>
    <wi>
      <wiid>476</wiid>
      <witype>Requirement</witype>
      <widesc>Created the SMA (Studio Mobile Access) solution, which allows the users to visualize online alarms and tag values from any remote device, such as a cell phone, PDA, or regular computer, using any web browser capable of displaying HTML pages.</widesc>
    </wi>
    <wi>
      <wiid>478</wiid>
      <witype>Requirement</witype>
      <widesc>Created a new option on the Help menu, called “Support Information”. This option displays information about the local system, and about the (remote) target system (if any) connected through the Execution Environment interface. The information displayed by this option is especially useful when requesting technical support.</widesc>
    </wi>
    <wi>
      <wiid>500</wiid>
      <witype>Requirement</witype>
      <widesc>It was created the option to run the product (runtime) as a “Service”, in addition to the existing default mode to run the product as a regular “Windows Application”.</widesc>
    </wi>
    <wi>
      <wiid>502</wiid>
      <witype>Requirement</witype>
      <widesc>Created option to compress files before sending them through the Execution Environment to the Remote Agent. Consult the product documentation (Execution Environment) for further information about how to enable this option.</widesc>
    </wi>
    <wi>
      <wiid>464</wiid>
      <witype>Change Request</witype>
      <widesc>Improved the internal structure of the Security System.</widesc>
    </wi>
    <wi>
      <wiid>471</wiid>
      <witype>Change Request</witype>
      <widesc>Improved the performance when scanning multiple channels along with computed channels from the FlukeDAQ device.</widesc>
    </wi>
    <wi>
      <wiid>546</wiid>
      <witype>Change Request</witype>
      <widesc>The FileWrite() built-in function was modified to support UNICODE format in addition to the already supported ASCII format.</widesc>
    </wi>
    <wi>
      <wiid>549</wiid>
      <witype>Change Request</witype>
      <widesc>Improved the error message displayed when an ActiveX control configured on the screen cannot the loaded. The improved message describes the possible causes of the error.</widesc>
    </wi>
    <wi>
      <wiid>555</wiid>
      <witype>Change Request</witype>
      <widesc>Enhanced the development environment to set the startup state of the following tasks to "Automatic" (instead of "Manual") when creating the first worksheet for each one of them, respectively: OPCClient, TCPClient, Database Client, DDE Client, and ODBC Client.</widesc>
    </wi>
    <wi>
      <wiid>558</wiid>
      <witype>Change Request</witype>
      <widesc>Created an option in the "Project Settings --&gt; Runtime Desktop" dialog to execute only the command for the topmost object, when clicking on objects that overlap.</widesc>
    </wi>
    <wi>
      <wiid>565</wiid>
      <witype>Change Request</witype>
      <widesc>Improved Import Wizard to configure the OPC Client Task to start automatically after creating OPC worksheets and set the scope of imported tags to "Server" instead of "Local".</widesc>
    </wi>
    <wi>
      <wiid>583</wiid>
      <witype>Change Request</witype>
      <widesc>The Text I/O dynamic was modified to display the warning message "Invalid entry. Please enter a numeric value." during the runtime, when the user attempts to enter a non-numerical value for a numeric tag (Boolean, Integer, or Real).</widesc>
    </wi>
    <wi>
      <wiid>598</wiid>
      <witype>Change Request</witype>
      <widesc>The default file type supported by the Import Wizard for the "TwinCAT PLC Database" was modified from "SYM" to "TPY".</widesc>
    </wi>
    <wi>
      <wiid>605</wiid>
      <witype>Change Request</witype>
      <widesc>The message "Verify Application was completed successfully. Check the Output window for a complete log of this command" will be displayed after finishing the execution of the Verify Application command from the Tools menu.</widesc>
    </wi>
    <wi>
      <wiid>606</wiid>
      <witype>Change Request</witype>
      <widesc>It was created a warning message to be displayed when saving a Trend worksheet, as long as the changes implemented in the Trend worksheet will result in incompatibility with the proprietary history files created previously by the same application.</widesc>
    </wi>
    <wi>
      <wiid>608</wiid>
      <witype>Change Request</witype>
      <widesc>It was created a new parameter called "SendEveryState" (under the section [ISSymbol]) for the &lt;ApplicationName&gt;.APP file. When this parameter is set with the value 0 (default), ISSymbol (Viewer, Secure Viewer, or Web Thin Client) sends every state (tag values) to the Server only for tags that are configured in the Driver or OPC Client worksheet, as long as the option "Driver and OPC" from "Project --&gt; Settings --&gt; Communication" is set to "Send Every State". When this parameter is set with the value 1, ISSymbol (Viewer, Secure Viewer, or Web Thin Client) sends every state (tag values) to the Server for all tags.</widesc>
    </wi>
    <wi>
      <wiid>614</wiid>
      <witype>Change Request</witype>
      <widesc>There were created additional options for project resolution when creating a new project or when converting the resolution of the current project. Furthermore, it was created an option where the user can customize any resolution (width and height) for the project, different from the pre-defined options.</widesc>
    </wi>
    <wi>
      <wiid>634</wiid>
      <witype>Change Request</witype>
      <widesc>The CEView program was modified to start the application faster, especially for applications that have thousands of lines configured in the Global Procedures interface.</widesc>
    </wi>
    <wi>
      <wiid>636</wiid>
      <witype>Change Request</witype>
      <widesc>Created read-only field SendEveryState, which is automatically set by the run-time and forces the graphical interface to report all the tag changes to the Server Module.</widesc>
    </wi>
    <wi>
      <wiid>639</wiid>
      <witype>Change Request</witype>
      <widesc>Created an option to configure a custom tag to trigger the MAIN DRIVER SHEET read commands. This parameter can be configured in the &lt;ApplicationName&gt;.APP, as follows:
[Options]
MainDrvAlwaysTrigger=BlinkSlow</widesc>
    </wi>
    <wi>
      <wiid>643</wiid>
      <witype>Change Request</witype>
      <widesc>The project (&lt;ApplicationName&gt;.APP file) can be configured to download external ActiveX controls and register them automatically on the Thin Client station. This algorithm was modified to show an error message if, after downloading and installing the control, we don't find it in the registry (probably because the user specified a wrong CLSID). Also modified to download the control using relative path (see Technical Reference manual for details)</widesc>
    </wi>
    <wi>
      <wiid>652</wiid>
      <witype>Change Request</witype>
      <widesc>Changed the TCP Client task to support IP:PORT in the "Server IP Address" field.</widesc>
    </wi>
    <wi>
      <wiid>654</wiid>
      <witype>Change Request</witype>
      <widesc>The screen editor was modified to resize objects proportionally (keeping the ratio between width and height) when using the handlers drawn on the corners of the selected object. When pressing the SHIFT key, the user is able to resize the object changing the ratio between its width and height.</widesc>
    </wi>
    <wi>
      <wiid>655</wiid>
      <witype>Change Request</witype>
      <widesc>The OPC Client task was modified to improve its reliability and report errors, if any, to the Output Window (LogWin) when connecting or communicating with third-party OPC Servers.</widesc>
    </wi>
    <wi>
      <wiid>657</wiid>
      <witype>Change Request</witype>
      <widesc>The TCP/IP Client task was modified to set the quality of the tags configured in its worksheets to BAD when the TCP/IP Client detects errors when trying to communicate with the remote TCP/IP Server. In order to enable the TCP/IP Client task to modify the quality of tags, the new parameter "SetQualityToBadOnError" from the [TCP] section of the &lt;ApplicationName&gt;.APP must be set to 1.</widesc>
    </wi>
    <wi>
      <wiid>663</wiid>
      <witype>Change Request</witype>
      <widesc>The Linked Symbol was enhanced, allowing the user to group Custom Properties in different categories and filter the properties per category when editing the objects. The new syntax supported by the Linked Symbol is "#Category.CustomProperty:DefaultValue", where the "Category" and the "DefaultValue" are optional.</widesc>
    </wi>
    <wi>
      <wiid>711</wiid>
      <witype>Change Request</witype>
      <widesc>CEView was enhanced to support the Picture object, available from “Edit --&gt; Past Link”. CEView supports picture files in the formats BMP and JPG.</widesc>
    </wi>
    <wi>
      <wiid>717</wiid>
      <witype>Change Request</witype>
      <widesc>The default setting from "Project --&gt; Setting --&gt; Communication --&gt; Driver and OPC" was modified for new applications. The new default setting is "Send every state" instead of "Send last state".</widesc>
    </wi>
    <wi>
      <wiid>780</wiid>
      <witype>Change Request</witype>
      <widesc>The Alarm/Event Control was enhanced to support a third optional column when configuring the initial sort.</widesc>
    </wi>
    <wi>
      <wiid>794</wiid>
      <witype>Change Request</witype>
      <widesc>Changed default for the Virtual Keyboard Show Hint configuration in Project-&gt;Settings-&gt;Runtime Desktop. The default is now enabled for new projects.</widesc>
    </wi>
    <wi>
      <wiid>839</wiid>
      <witype>Change Request</witype>
      <widesc>The graphic interface was enhanced to support background pictures for screens with resolution as large as 10000 x 10000 (pixels).</widesc>
    </wi>
    <wi>
      <wiid>877</wiid>
      <witype>Change Request</witype>
      <widesc>The built-in SaveAlarmFile() function was enhanced to support the Database format, in addition to the Proprietary and Binary formats, which were supported previously.</widesc>
    </wi>
    <wi>
      <wiid>924</wiid>
      <witype>Change Request</witype>
      <widesc>Increased the size of the "Yes" and "No" buttons in the confirm dialog.</widesc>
    </wi>
    <wi>
      <wiid>455</wiid>
      <witype>Issue</witype>
      <widesc>Modified the algorithm implemented by the 'Replace' feature of the 'Object Properties' dialog window, in order to handle properly specific syntaxes, such as: Array indexes with expression (e.g.: Tag[TagID+1]), and class members and tag fields associated to the same custom property (e.g.: #Prop:Class.Member and #Prop:Class.Member-&gt;Field).</widesc>
    </wi>
    <wi>
      <wiid>458</wiid>
      <witype>Issue</witype>
      <widesc>Improved the algorithm for the Alarm Deadband Time to make sure it works properly, even if the internal clock of the station moves backwards.</widesc>
    </wi>
    <wi>
      <wiid>462</wiid>
      <witype>Issue</witype>
      <widesc>Modified Secure Viewer to display the tag values properly when switching to screens after logging with different users more than once on the startup screen.</widesc>
    </wi>
    <wi>
      <wiid>465</wiid>
      <witype>Issue</witype>
      <widesc>Modified Web Thin Client control (ISSymbol) to support the "Print Preview" option from the Web Browser (Internet Explorer).</widesc>
    </wi>
    <wi>
      <wiid>480</wiid>
      <witype>Issue</witype>
      <widesc>Modified the DirDelete() built-in function to avoid deleting all files from the root directory of the C drive when executing the function with no parameters.</widesc>
    </wi>
    <wi>
      <wiid>484</wiid>
      <witype>Issue</witype>
      <widesc>The algorithm that sorts the addresses in the communication driver MAIN DRIVER SHEET was modified to guarantee that the addresses are properly organized in virtual communication groups.</widesc>
    </wi>
    <wi>
      <wiid>486</wiid>
      <witype>Issue</witype>
      <widesc>The error messages indicating that VBScript is not supported by the device are no longer displayed when the user switches from one screen to another. When the device does not support VBScript, the error message will be displayed only once when running the application.</widesc>
    </wi>
    <wi>
      <wiid>541</wiid>
      <witype>Issue</witype>
      <widesc>Modified the GetLine() function to return the value of the first row of the text file properly when the format of the file is UNICODE. The initial UNICODE char (0xFEFF) used to indicate the file format is properly ignored by the function.</widesc>
    </wi>
    <wi>
      <wiid>542</wiid>
      <witype>Issue</witype>
      <widesc>The graphic interface was modified to support the DayOfYear system tag both on the Server and on the Thin Client stations.</widesc>
    </wi>
    <wi>
      <wiid>543</wiid>
      <witype>Issue</witype>
      <widesc>Modified Execution Environment to support the "Microsoft ActiveSync" connection type when linking the development environment with devices running Windows Mobile v5.0 or v6.0.</widesc>
    </wi>
    <wi>
      <wiid>544</wiid>
      <witype>Issue</witype>
      <widesc>The RunVBScript() built-in function was modified to avoid memory leaking.</widesc>
    </wi>
    <wi>
      <wiid>548</wiid>
      <witype>Issue</witype>
      <widesc>Grid column editor was modified to avoid exceptions.</widesc>
    </wi>
    <wi>
      <wiid>550</wiid>
      <witype>Issue</witype>
      <widesc>Modified the product to guarantee that the user is able to add shared tags in applications created under Windows Vista.</widesc>
    </wi>
    <wi>
      <wiid>554</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Trend Control to avoid generating overflow errors in VBScripts when a pen configured in the Trend Control has a very low value (e.g.: 1e-100).</widesc>
    </wi>
    <wi>
      <wiid>562</wiid>
      <witype>Issue</witype>
      <widesc>The Trend Task was modified to support String tags. When the Trend History Format is set to "Proprietary", the value of the String tag is converted to a numeric value before being saved into the history file.</widesc>
    </wi>
    <wi>
      <wiid>563</wiid>
      <witype>Issue</witype>
      <widesc>The Viewer process was modified to display the value of the "Description" tag field properly (e.g.: TagName-&gt;Description).</widesc>
    </wi>
    <wi>
      <wiid>575</wiid>
      <witype>Issue</witype>
      <widesc>Modified the linked symbols to display property tooltips properly even when using grouped properties.</widesc>
    </wi>
    <wi>
      <wiid>581</wiid>
      <witype>Issue</witype>
      <widesc>The screen editor was modified to keep the relative position among the selected objects, even when moving them through the borders of the screen.</widesc>
    </wi>
    <wi>
      <wiid>596</wiid>
      <witype>Issue</witype>
      <widesc>Fixed the memory leaking issue when generating and displaying event messages with more than 64 characters (each).</widesc>
    </wi>
    <wi>
      <wiid>597</wiid>
      <witype>Issue</witype>
      <widesc>The email notification from the Alarm Task was modified to avoid crashing after attempting to send several emails unsuccessfully.</widesc>
    </wi>
    <wi>
      <wiid>601</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Import Wizard for OPC Server Databases to support more than 4096 tags from the OPC Server, as long as the current license allows it.</widesc>
    </wi>
    <wi>
      <wiid>603</wiid>
      <witype>Issue</witype>
      <widesc>Removed the "Remote" option from the Import Wizard for Studio Database to avoid instability issues on the current architecture.</widesc>
    </wi>
    <wi>
      <wiid>617</wiid>
      <witype>Issue</witype>
      <widesc>The graphic module was modified to guarantee that the values for tag fields are properly retrieved, even when using indirect tags (@TagName-&gt;TagFieldName) to access the tag field value.</widesc>
    </wi>
    <wi>
      <wiid>618</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Grid object to avoid errors when opening a screen with a Grid object (Data Source = Class Tag) where the same member of the class tag was configured in more than one column of the Grid object. The error would occur only if the Grid object was configured in the startup screen.</widesc>
    </wi>
    <wi>
      <wiid>623</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Viewer task to avoid exception errors when defining an expression for custom properties in object dynamics (e.g.: #CustomPropertyName:TagName&gt;10). The error occurred only when running the application under Windows CE.</widesc>
    </wi>
    <wi>
      <wiid>641</wiid>
      <witype>Issue</witype>
      <widesc>The development environment was modified to support the built-in functions StartTask(), EndTask(), and IsTaskRunning() on any interface that supports expressions, even if the project is set to CEView (Target System).</widesc>
    </wi>
    <wi>
      <wiid>648</wiid>
      <witype>Issue</witype>
      <widesc>The Smart Message object was modified to display the last message configured in the object, even when it is configured to blink.</widesc>
    </wi>
    <wi>
      <wiid>650</wiid>
      <witype>Issue</witype>
      <widesc>The Security System was modified to make sure that Studio is able to load the application when the option "Use preferentially the Remote Security System" from the Security System is enabled, even if the Remote Security System station is not available.</widesc>
    </wi>
    <wi>
      <wiid>658</wiid>
      <witype>Issue</witype>
      <widesc>The driver task was modified to avoid exception errors when running projects configured with more than 4095 tags in the MAIN DRIVER SHEET. The problem occurred only with drivers that did not impose the maximum block size for virtual groups from the MAIN DRIVER SHEET.</widesc>
    </wi>
    <wi>
      <wiid>659</wiid>
      <witype>Issue</witype>
      <widesc>The Driver task was modified to guarantee that the writing commands from the MAIN DRIVER SHEET have higher priority than the reading commands from the same MAIN DRIVER SHEET.</widesc>
    </wi>
    <wi>
      <wiid>668</wiid>
      <witype>Issue</witype>
      <widesc>The Thin Client control (ISSymbol) was modified to improve the performance when switching screens, especially when the Primary Server is not available and the Thin Client station is connected to the Secondary Server (redundancy).</widesc>
    </wi>
    <wi>
      <wiid>674</wiid>
      <witype>Issue</witype>
      <widesc>Improved Import Wizard to configure the Driver Task to start automatically after creating driver worksheets.</widesc>
    </wi>
    <wi>
      <wiid>698</wiid>
      <witype>Issue</witype>
      <widesc>The Execution Environment was modified to make the Serial Port configuration persistent.</widesc>
    </wi>
    <wi>
      <wiid>703</wiid>
      <witype>Issue</witype>
      <widesc>The Remote Agent for PC (e.g.: Windows XP/Vista/2003 Server) was modified to avoid conflicts when trying to run it along with the Studio runtime.</widesc>
    </wi>
    <wi>
      <wiid>707</wiid>
      <witype>Issue</witype>
      <widesc>The settings from the “Project Settings” dialog were updated to match the actual default settings for title bar, menu, and status bar.</widesc>
    </wi>
    <wi>
      <wiid>708</wiid>
      <witype>Issue</witype>
      <widesc>The device driver for the USB Hardkey was updated to solve incompatibility issues with 64-bits operating systems, such as Windows Vista 64-bits or Windows 2008 64-bits.</widesc>
    </wi>
    <wi>
      <wiid>716</wiid>
      <witype>Issue</witype>
      <widesc>The PrintWindow() built-in function was modified to run properly under Windows CE.</widesc>
    </wi>
    <wi>
      <wiid>739</wiid>
      <witype>Issue</witype>
      <widesc>The Studio ADO Gateway (StADOSvr.exe) was modified to support timestamp with milliseconds precision for the history tasks: Alarm, Event, and Trend.</widesc>
    </wi>
    <wi>
      <wiid>740</wiid>
      <witype>Issue</witype>
      <widesc>Resolved problem with daylight savings when running the Fluke DAQ devices.</widesc>
    </wi>
    <wi>
      <wiid>752</wiid>
      <witype>Issue</witype>
      <widesc>Modified algorithm for Print Preview to prevent problems when using the system close button (upper right x) to close the Print Preview window.</widesc>
    </wi>
    <wi>
      <wiid>758</wiid>
      <witype>Issue</witype>
      <widesc>Modified VBScript compilation to properly handle pointers to integers. The current algorithm was causing the assignment @MyIntegerPointer=1 to be handled as @MyIntegerPointer=True and as a result the integer tag being pointed to would receive -1.</widesc>
    </wi>
    <wi>
      <wiid>759</wiid>
      <witype>Issue</witype>
      <widesc>The following tag fields were modified to assume the value 1 when writing any value different from 0 to them: “Ack”, “AlrDisable”,  and “Unack”.</widesc>
    </wi>
    <wi>
      <wiid>760</wiid>
      <witype>Issue</witype>
      <widesc>The hardkey interface was updated to support the Sentinel USB Hardkey under Windows XE Embedded (WinXPe).</widesc>
    </wi>
    <wi>
      <wiid>764</wiid>
      <witype>Issue</witype>
      <widesc>Fixed problem with Trend Control when saving the Min/Max values for pens that have not been added to the trend run-time. The trend was saving the Min/Max as 0 for these pens and if the user inserted them after loading the configuration (which happens when you close and open a trend screen) the pen would be inserted with Min/Max of 0.</widesc>
    </wi>
    <wi>
      <wiid>767</wiid>
      <witype>Issue</witype>
      <widesc>The behavior of the State field used to filter messages from the Alarm/Event Control object was modified to support the following options:
0: No filter (all states)
1: Active and not acknowledged
2: Active and acknowledged
3: Normalized and acknowledged
4: Normalized and not acknowledged</widesc>
    </wi>
    <wi>
      <wiid>771</wiid>
      <witype>Issue</witype>
      <widesc>The Import Wizard for the “TwinCAT PLC database” was modified to avoid setting the type of String tags imported from the TPY file as Real tags.</widesc>
    </wi>
    <wi>
      <wiid>777</wiid>
      <witype>Issue</witype>
      <widesc>The behavior of the screen dynamics was modified to avoid triggering command dynamic when the object is updated by other dynamics.</widesc>
    </wi>
    <wi>
      <wiid>786</wiid>
      <witype>Issue</witype>
      <widesc>Modified the option "Import Strings" in the translation tool to include the header texts from objects that support column header (Alarm, Trend Legend and Grid).</widesc>
    </wi>
    <wi>
      <wiid>796</wiid>
      <witype>Issue</witype>
      <widesc>Modified the built-in function Hst2Txt() to prevent exceptions when invalid parameters are specified.</widesc>
    </wi>
    <wi>
      <wiid>799</wiid>
      <witype>Issue</witype>
      <widesc>Fixed problem with functions DateTime2Clock, ClockGetDate and ClockGetTime when running on Windows Vista.</widesc>
    </wi>
    <wi>
      <wiid>800</wiid>
      <witype>Issue</witype>
      <widesc>Modified the screen editor to avoid asking if the user wants to save screens with the Trend object, even if the user did not implemented changes on it.</widesc>
    </wi>
    <wi>
      <wiid>804</wiid>
      <witype>Issue</witype>
      <widesc>Modified the development environment not to reset tag values when the run-time is running and the same application is loaded in the development environment by using the command "RunStudio AppName" or by double clicking in the application file.</widesc>
    </wi>
    <wi>
      <wiid>813</wiid>
      <witype>Issue</witype>
      <widesc>Improved the performance of TWCAT import wizard and implemented algorithm to ignore pointers when importing.</widesc>
    </wi>
    <wi>
      <wiid>860</wiid>
      <witype>Issue</witype>
      <widesc>Modified the built-in Virtual Keyboards to display the correct ASCII character when pressing the space bar on the Virtual Keyboard.</widesc>
    </wi>
    <wi>
      <wiid>861</wiid>
      <witype>Issue</witype>
      <widesc>Trend control was modified to resolve problem with break interval when the break happens between the first two samples and then to consecutive samples.</widesc>
    </wi>
    <wi>
      <wiid>879</wiid>
      <witype>Issue</witype>
      <widesc>The graphic module for Windows CE was modified to avoid displaying "#" characters instead of actual values. The problem would occur when configuring specific expressions with Custom Properties.</widesc>
    </wi>
    <wi>
      <wiid>892</wiid>
      <witype>Issue</witype>
      <widesc>Fixed problem with Pocket PC that would generate exceptions when switching between screens in some specific Windows CE devices.</widesc>
    </wi>
    <wi>
      <wiid>893</wiid>
      <witype>Issue</witype>
      <widesc>The device driver for the USB Hardkey (beige) was updated to avoid memory leaking that could result in a system crash.</widesc>
    </wi>
    <wi>
      <wiid>895</wiid>
      <witype>Issue</witype>
      <widesc>Modified hardkey license interface to address compatibility issues with Windows 2008.</widesc>
    </wi>
    <wi>
      <wiid>908</wiid>
      <witype>Issue</witype>
      <widesc>Modified the Viewer module not to reload screens when tags with retentive parameters have their parameter values changed.</widesc>
    </wi>
    <wi>
      <wiid>911</wiid>
      <witype>Issue</witype>
      <widesc>Modified Linked Symbols capability to support combo boxes even on HMIs with ARMV4I processors.</widesc>
    </wi>
    <wi>
      <wiid>913</wiid>
      <witype>Issue</witype>
      <widesc>Fixed problem with Text I/O when used on Screens with Hide option enabled. The hide would cause the Text I/O to be loaded only in the first time that you open the screen.</widesc>
    </wi>
  </version>
  <version>
    <releaseversion> v6.1 + Service Pack 6 - Known Issues</releaseversion>
    <releasedate>Monday, November 30, 2009</releasedate>
    <wi>
      <wiid>604</wiid>
      <witype>Issue</witype>
      <widesc>The column to delete alarm messages from the Alarm/Event object, when configured as the first column, is displayed too small on Windows Vista. [WORKAROUND]: Configure any other field as the first column.</widesc>
    </wi>
    <wi>
      <wiid>626</wiid>
      <witype>Issue</witype>
      <widesc>Remote on-line screen update does not work when downloading large screen files to specific devices. [WORKAROUND]: Stop the application and execute the "Send Application" command.</widesc>
    </wi>
    <wi>
      <wiid>715</wiid>
      <witype>Issue</witype>
      <widesc>The Web Tunneling Gateway is not installed automatically on Windows 64-Bits. [WORKAROUND]: Install the Web Tunneling Gateway manually, executing the WebGtw.exe program from the \BIN sub-folder of Studio.</widesc>
    </wi>
    <wi>
      <wiid>757</wiid>
      <witype>Issue</witype>
      <widesc>The Message Box from VBScript is displayed behind the screen when called from a background script. [WORKAROUND]: Call the Message Box from the Graphic Script, based on the condition triggered by the background script.</widesc>
    </wi>
    <wi>
      <wiid>873</wiid>
      <witype>Issue</witype>
      <widesc>When the user has only one pen in the trend and the Min/Max is not specified, the trend uses the point color to show the label instead of using the Y Axis font color. [WORKAROUND]: Add a second pen to the Trend Control and make the second pen invisible.</widesc>
    </wi>
    <wi>
      <wiid>884</wiid>
      <witype>Issue</witype>
      <widesc>Thin Client stations take a long time to load some screens for the first time. [WORKAROUND]: Configure objects on the screen with the tags used in the screen script. For example, transparent rectangle  with tags in the Caption.</widesc>
    </wi>
    <wi>
      <wiid>894</wiid>
      <witype>Issue</witype>
      <widesc>Evaluation mode does not work on Windows Vista and Windows 7. [WORKAROUND]: Run the development environment at least once as Administrator (right-click &gt; Run as Administrator).</widesc>
    </wi>
    <wi>
      <wiid>933</wiid>
      <witype>Issue</witype>
      <widesc>On computers with limited temporary storage Secure Viewer sometimes displays background images different from the ones created for the screen. [WORKAROUND]: Delete the user temporary files to allow enough space for Secure Viewer temporary files.</widesc>
    </wi>
    <wi>
      <wiid>1201</wiid>
      <witype>Issue</witype>
      <widesc>Batch file load fails on Trend object when using Database format for Trend task [WORKAROUND]: Lookup the batchHistory table, retrieve the Start_Date and End_Time, calculate the Duration and pass those paramters to the Trend Object without using Batch on it.</widesc>
    </wi>
    <wi>
      <wiid>1271</wiid>
      <witype>Issue</witype>
      <widesc>Standard Driver Sheet accepts tag fields in the Tag Name column, however the Write on Tag Change command does not work as expected in this condition [WORKAROUND]: Either configure the "Driver and OPC" communication interface to implement "Send Last State" (instead of "Send Every State"),  or configure just a tag instead of a tag field in the Tag Name column of the Standard Driver Sheet.</widesc>
    </wi>
    <wi>
      <wiid>1297</wiid>
      <witype>Issue</witype>
      <widesc>Kbdblock2.sys is not being installed properly on some OEM devices when installing Secure Viewer [WORKAROUND]: Contact technical support for manual installation procedures.</widesc>
    </wi>
  </version>
</releasenotes>